Configuring a CalComp M971/M981 on Windows NT 3.5 (LPD).

Configuring a CalComp M971/M981 on Windows NT 3.5 (LPD).
Technical Support Hot Line 1-800-CALCOMP (800-225-2667) Updated 8 December 1995
Windows NT 3.5 supports printing to lpd printer or print servers.
All CalComp M971/M981's with firmware 3.5 or above will work under
Windows NT 3.5.
1. To install lpd support on Windows NT 3.5
- Open Control Panel and select the Network icon.
- Click the Add Software button in the "Network Software and
Adapter cards" box.
- Select "TCP/IP Protocol and Related and component" from the
network software pulldown list, and then click Continue.
- Click the check box next to "TCP/IP Network Printing support"
(an "X" should appear in it) to select this component, and then
click Continue.
- Insert the driver diskette or CD-ROM disc and load the drivers.
- When the drivers have loaded, reboot the system.
2. Set the IP address on the M971/M981.
- From the DOS prompt enter
ARP -s [IP Address for 981/971] [981/971 Ethernet Address][Host Address].
Example: ARP -s 140.120.10.100 00-C0-E2-00-01-4D 140.120.10.001
- From the Accessories group in Program Manager, select the Telnet icon.
- Select Connect, then select Remote System.
- Enter the IP Address for the 981/971: (Example 140.120.10.100)
Enter 2002 for port:
- Click on the Connect button.
- Type ! to enter monitor.
- Type yes to enter monitor.
- Enter i and the IP Address (Example i 140.120.10.100)
to set the M971/M981 IP address.
- Enter r to reset M971/M981.
3. To add an lpd printer using the M971/M981 to Windows NT 3.5
- Open the Control Panel and select the Printers icon.
- From the menu bar, click on Printers and select Create Printers.
- Enter the name you wish to give this printer in the Name Field.
- Select the printer driver from the pulldown list next to Printer Driver.
- In the Print To: box, scroll down the list and select Other.
- Select the LPR Port from the "Print Destinations" pop-up window and then
click on the OK button.
- Enter the IP address of the M971/M981 in the Name or address of host
providing the lpd field.
- Enter the appropriate queue name* in the Name of Printer for the
M981/M971.
* Valid queue name:
raw Send data with no header and no translation. Use raw-p for parallel and
raw-s for serial.
pcl Assumes the data is PCL and sends a text banner. No carriage returns
are added and a formfeed is sent at the end of the job unless it is
suppressed through the monitor. Use pcl-p for parallel and pcl-s
for serial.
ps Writes postscript, and sends a Control+D at the end of the print job.
Also sends a PostScript banner page at the end of the print job.
Both of these can be suppressed using telnet via the monitor. Use ps-p
for parallel and ps-s for serial.