Setup AutoCAD 9,10, and 11 with Solus 4 544xx Serial Port:

AutoCAD 9,10, and 11 with Solus 4 544xx Serial Port:
Technical Support Hot Line 1-800-CALCOMP (1-800-225-2667)
Updated: 30 April, 1996
Hardware Connection Requirements:
PC Host Computer with an operational serial port (i.e. COM1, COM2).
A straight through serial cable (50 ft. max), no wires crossed, and a
Null Modem adapter part #21617-0019 to plotter COM _1, or COM _2 port.
CalComp 544xx Plotter must be connected to a PC directly for this
configuration. Network systems, serial buffer boxes, and/or plot
spool programs may require different communication parameter settings.
1. Setup 54424, 54436 Plotter:
- Turn plotter on, when Online appears on the LCD plotter is ready.
- Press the Scroll key until More Options is displayed. Press the
Select key.
- Press the Scroll key until Port Setup is displayed. Press the
Select key.
- Press the Scroll key until COM_1 (if using Com_1) is displayed.
Press Select key.
- Press the Scroll key until Manual Setup is displayed. Press the
Select key.
- Press the Scroll key until Dead Job Time is displayed. Press the
Select key.
- Press the Scroll key until 60 sec is displayed. Press the Select key.
- Press the Scroll key until Dead Job Action is displayed. Press
the Select key.
- Press the Scroll key until Force is displayed. Press the Select key.
- Press the Scroll key until Steps per Inch is displayed. Press the
Select key.
- Press the Scroll key until 2032 is displayed. Press the Select key.
- Press the Scroll key until Baud Rate is displayed. Press the
Select key.
- Press the Scroll key until 9600 is displayed. Press the Select key.
- Press the Scroll key until Char Framing is displayed. Press the
Select key.
- Press the Scroll key until 7-E-1 is displayed. Press the Select key.
- Press the Scroll key until Protocol is displayed. Press the Select key.
- Press the Scroll key until CTS is displayed. Press the Select key.
- Press the Scroll key until Exit Manual Setup is displayed. Press
the Select key.
- Press the Scroll key until Exit Port Setup is displayed. Press
the Select key.
- Press the Scroll key until Save to User # is displayed. Press the
Select key.
- Press the Scroll key until 1 is displayed, or the user # you wish
to use (1-10). Press the Select key.
- Press the Scroll key until Exit to Main Menu is displayed. Press
the Select key.
- Press the Scroll key until Online is displayed. Press the Select key.
2. Use EDIT or EDLIN to Add line to AUTOEXEC.BAT file to define COM Port
(Add after PATH statement):
MODE COM1:9600,E,7,1,P (if using serial port COM1).
MODE COM2:9600,E,7,1,P (if using serial port COM2).
3. Setup AutoCAD Release 9,10,11:
- Start up AutoCad. At Main Menu choose 5 - Configure AutoCAD.
- At Configuration Menu choose - Configure operating parameters.
- At Operating parameters choose 3 - Default plot file name. Enter COM1
(if using serial port 1).
- Exit to Configuration Menu.
- At Configuration Menu choose 5 - Configure plotter.
- Do you want to select a different one ? = YES.
- From Available Plotters choose 5 - CalComp 906 / 907 / PCI. *
- From Supported Models choose 1 - 104X Plotter.
- Number of pens is 16.
- Step Size per inch is 2032.
- Do you want to use XON/XOFF = YES.
- Enter port name, or address in hexadecimal = COM1.
(Selection entered here will not actually be used).
- Would you like to calibrate your plotter ? = NO.
- Write the plot to a file ? = YES.
- Size Units ( Inches or Millimeters) = I (Inches).
- Plot Origin in inches = 0.00,0.00.
- Enter size or Width, Height in inches = 34.25, 23 (for 36x24 sheet)
or desired sheet size.
- Rotate plot (0 - 90 - 180 - 270) = 0.
- Do you want to change anything ? = NO.
- Pen width in inches = 0.010.
- Adjust area fill boundaries for pen width ? = NO.
- Remove hidden lines ? = NO.
- Plotted Inches = Drawings Units or Fit = F (Fit).
- Exit to configuration Menu, Exit to Main Menu, Keep
Configuration Changes = YES.
*An ADI Driver for these versions of AutoCad is available through our
website (http://www.calcomp.com). The filename you need to download is
CALPROGS.ZIP. Use PKUNZIP to uncompress this file. This file also
contains a readme file with instructions on how to install and
configure. With the ADI driver you will have a selection of 126 pens
and also long plot capabilities.