What kind of cable do I need for the plotter?


What kind of cable do I need for the plotter?

Models: Solus 4 54424/54436 and DM-600/800 53336/53436

The order P/N for the Solus 4 User's Guide is M0016-280
The order P/N for the DM-600/800 User's Guide is M0016-420

All of the above CalComp plotters fully support the RS-232C standard for
serial communications and the CENTRONICS standard for parallel data
transfer.

A.   CENTRONICS PARALLEL CABLE

     1.   FOR IBM PC S & COMPATIBLES, MACINTOSH, SUN, HP, AND ALL UNIX
          WORKSTATIONS WHICH SUPPORT THE CENTRONICS STANDARD:

          a.   The maximum length for a standard Centronics parallel
               cable is 12'. This limit is the current industry-wide
               standard. CalComp cannot guarantee that the integrity of
               the plot data being transferred will be reliable beyond
               12'. In addition, a heavy duty parallel cable is always
               recommended. The 12' limit CAN be exceeded if you
               purchase a specially designed cable (see Notes #1b and
               #C below).

          b.   CalComp manufactures high quality, double-shielded
               Centronics parallel cables INCLUDING a 25' cable. To
               order a parallel cable from CalComp, call (1-800) 225-
               2667 and use the following order part numbers:

               For a 12 foot Centronics cable:    18735-0129

               For a 25 foot Centronics cable:    717960-9


B.   RS-232 PORT SERIAL CABLES (for plot data ports and the terminal
     port):

     Note:     The maximum length for a standard serial cable is 50'.
               CalComp cannot guarantee that the integrity of the plot
               data being transferred will be reliable beyond 50'. This
               limit is the current industry-wide standard. A heavy
               duty double-shielded type cable is recommended. The 50'
               limit CAN be exceeded if you purchase a specially
               designed cable (see Note #C below). This limit applies
               to ALL platforms listed below.

     1.   FOR IBM PC S/COMPATIBLES WITH A 25-PIN (DB25) RS-232 SERIAL
          PORT:

          The two serial ports both require NULL MODEM type cables.
          CalComp has a heavy duty Null-Modem type cable available. The
          order P/N for this cable is 754050-3.

          A straight (MODEM) cable, such as CalComp's P/N 11772-0250,
          may also be used if a NULL-MODEM adapter is attached. A Null-
          Modem adapter may be ordered from CalComp. The P/N for this
          adapter is 21617-0019.

          a.   Most PC s are setup as DTE (Data Terminal Equipment)
               devices with 25 pin RS-232 serial ports. The DM-600/800
               plotters are also DTE devices. The cable to use in when
               the terminal or PC is DTE is a DB25 (25-pin) NULL-MODEM
               type RS-232 serial cable  (transmit and receive pin
               wires 2 and 3 are to be crossed).  CalComp manufactures
               a heavy duty, 25 pin, female-to-male NULL-MODEM cable.
               The order P/N for this cable is 754050-3. This cable can
               be ordered by calling CalComp at 1-800-225-2667.

               If you wish to build your own cable, here is the wiring
               diagram for the IBM standard 25-to-25 pin, female-to
               male serial cable (pin connections not shown are not
               required): The Null Modem Adapter IS NOT required for
               this cable.

                      IBM-PC                          Plotter Port:
                     25 pin female                     25 pin male
                     connector         connect as       connector
                       Pin #           shown below         Pin #
                    ==============================================
                        1  --------------------------------  1
                        2  --------------------------------  3
                        3  --------------------------------  2
                        4  --------------------------------  6 & 8
                        5  --------------------------------  20
                        6  --------------------------------  4
                        7  --------------------------------  7
                        8  --------------------------------  4
                        20 --------------------------------  5


     2.   FOR IBM PC S & COMPATIBLES WITH A 9-PIN (DB9) RS-232 SERIAL
          PORT:

          NOTE: You MUST attach the CalComp Null Modem Adapter (P/N
          21716-0019) to the following IBM-PC DB9 to DB25 cable:

          a.   The DB9 to 25-pin required (for the IBM standard 9-pin
               port, female-to-male cable) is not available from
               CalComp. This type of cable is widely available from
               most computer retailers. Here is the Radio Shack P/N for
               a 6 foot cable (DB9 to DB25, female-to-male):

                         Radio Shack Catalog #  26-269

               If you wish to lengthen this cable, attach a 25pin-to-
               25pin (female-to-male), straight-through cable, such as
               CalComp's P/N 11772-0250 (25' cable) or 11772-0102 (10'
               cable).

          b.   If you wish to build your own cable, here is the wiring
               diagram for the IBM standard 9-to-25 pin, female-to male
               serial cable (pin connections not shown are not required):


                      PC Port:                       Plotter Port:
                    9 pin female                      25 pin male
                     connector      connect as         connector
                       Pin #        shown below          Pin #
                    ============================================
                        1  ------------------------------  8
                        2  ------------------------------  3
                        3  ------------------------------  2
                        5  ------------------------------  7
                        6  ------------------------------  6
                        7  ------------------------------  4
                        8  ------------------------------  5



     3.   FOR THE MACINTOSH:

          Note:     The 50' cable limit also applies to the Mac. To
                    extend the length of either of the cables  listed,
                    add one of CalComp's straight-through cables (P/N
                    11772-0250 for a 25' cable and 11772-0102 for a 10'
                    cable).

          a.   On the back of the plotter are 3 ports, the one marked
               COM_1/OPCOM is an  RS-232 25-pin serial port (female,
               DB25). This port is configured by the factory  for
               OPCOM. It cannot be used for plot data unless the OPCOM
               link is switched off. You can switch COM_1 from OPCOM to
               a plot data port at the Control Panel (see your Solus 4
               or DM-600/800 User's Guide for details on how to do
               this).

          b.   To make a serial connection you need CalComp's Mac cable
               P/N 16623-0029 (12' cable) or 16623-0011 (6' cable) AND
               the CalComp Null Modem Adapter P/N 21617-0019. This
               adapter should have been included as a standard item
               when the plotter was purchased. The CalComp cable
               connects directly to the Mac's MODEM port and the
               adapter end connects to the Solus 4 or DM-600/800's
               COM_2 port. If you wish to extend the lengthen this
               cable (up to 50'), add a straight-through extension
               cable (CalComp P/N 11772-020 is a 25' heavy duty
               extension cable).

          c.   Another way to make a serial connection with the Mac is
               to use an ImageWriter One (Mini DIN-8) serial cable
               (connected directly to the Mac) with a different CalComp
               adapter (then the one mentioned above) attached (CalComp
               P/N 21616-0010). The ImageWriter One cable connects
               directly to the Mac's MODEM port and the adapter end
               connects to the Solus 4 or DM-600/800's COM_2 port. If
               you wish to extend the lengthen this cable (up to 50'),
               add a straight-through extension cable (CalComp P/N
               11772-020 is a 25' heavy duty extension cable).

          d.   If you wish to build your own Mac cable; here is the
               wiring diagram for the Mac serial cables offered by
               CalComp (P/N's 16623-0029 and 16623-0011)

               REMEMBER: You must attach the Null modem Adapter (P/N
               21617-0019) to the plotter (25 pin) end of this cable.

               Note:     Pin connections not shown are not required

                       MAC Port:                       Plotter Port:
                       8-pin male                       25 pin male
                    cable connector     connect as       connector
                         Pin #          shown below         Pin #
                    ===============================================
                        1  -------------------------------  20
                        2  -------------------------------  5 & 8
                        3  -------------------------------  2
                        4  -------------------------------  1 & 7
                        5  -------------------------------  3
                        8   ------------------------------  1 & 7



     4.   UNIX WORKSTATIONS:

          a.   SUN SPARC/IPC WORKSTATIONS:

               Connect a straight-through (female-to-male) MODEM cable
               AND a 25-to-25pin, male-to male adapter, to a standard
               SUN Mini DIN-8 to 25 pin (male-to-female) serial cable.

               The standard SUN Min-DIN-8 serial cable may be purchased
               directly from SUN MICROSYSTEMS. Another source which can
               be recommended as a supplier of SUN cable and
               connectivity products is NewData Inc. Call NewData at
               (908) 842-5757 and request information on their cable
               P/N 6642 (or equivalent).

               SUN SERIAL CONNECTION SUMMARY:

               i.   Use a standard SUN Mini DIN-8 male-to-female serial
                    cable (the female end is a 25-pin connector).

               ii.  Use a standard 25-pin, male-to-male adapter.
                    Connect this adapter directly to the female end of
                    the SUN cable. A 25-pin male-to-male adapter is
                    available from CalComp. The P/N is 14450-0253.

               iii. Use a 25 pin female-to-male NULL MODEM CABLE. The
                    order  P/N for CalComp's Null Modem cable is
                    754050-3

                    NOTE: Another way to connect up the plotter is to
                    substitute the Null Modem cable for a straight-
                    through MODEM cable and attach the Null Modem
                    Adapter, CalComp P/N 21617-0019 to the plotter
                    connector end of the cable. The order P/N for a 25'
                    MODEM cable is 11772-0250.

               iv.  To order the CalComp cable and adapter, call 1-800-
                    225-2667.


          b.   HP 9000 WORKSTATIONS

               NOTE: CalComp does not provide a serial cable for HP
               workstations.

               The following is a known working pin-out for CalComp
               plotters and the HP 9000. This cable pin-out is a
               reference only. For further information, please consult
               with your HP Workstation documentation and technical
               support services.

               REMEMBER: You must attach the Null modem Adapter (P/N
               21617-0019) to the plotter (25 pin) end of this cable.

                        HP                            Plotter Port:
                       9000                             25 male
                     connector       connect as        connector
                       Pin #        shown below           Pin #
                    ==============================================
                        1  --------------------------------  8
                        2  --------------------------------  3
                        3  --------------------------------  2
                        4  --------------------------------  20
                        5  --------------------------------  7
                        6  --------------------------------  6
                        7  --------------------------------  4
                        8  --------------------------------  5
                        9  --------------------------------  22



          c.   SILICON GRAPHICS WORKSTATIONS:

               NOTE: CalComp does not provide a serial cable for
               Silicon workstations.

               The following is a known working pin-out for CalComp
               plotters and Silicon Graphics Workstations. This cable
               pin-out is a reference only. For further information,
               please consult with your Silicon Graphics Workstation
               documentation and technical support services.

               REMEMBER: You must attach the Null modem Adapter (P/N
               21617-0019) to the plotter (25 pin) end of this cable.


                      Silicon                       Plotter Port:
                     Graphics                        25 pin male
                     connector      connect as         connector
                       Pin #       shown below           Pin #
                    ============================================
                        2  ------------------------------  2
                        3  ------------------------------  3
                        4  ------------------------------  4
                        5  ------------------------------  5
                        7  ------------------------------  7
                        8  ------------------------------  8
                        9  ------------------------------  20



          d.   IBM RS-6000 (RISC) WORKSTATION:

               Use CalComp cable P/N 754050-3 for the IBM RS-6000.
               Order from CalComp by calling, 1-800-225-2667.

               The following is a known working pin-out for CalComp
               plotters and IBM RS-6000 workstations. The cable is a
               female-to-male DB25 (both ends) NULL MODEM type cable.
               This cable pin-out is a reference only. For further
               information, please consult your IBM RS-6000
               documentation and technical support services.

               REMEMBER: You must attach the cable adapter (P/N 21617-
               0019) to the plotter (25 pin) end of this cable.

                    IBM RS-6000                       Plotter Port:
                    25 pin female                     25 pin male
                     connector        connect as        connector
                       Pin #          shown below         Pin #
                    ==============================================
                        1  --------------------------------  1
                        2  --------------------------------  3
                        3  --------------------------------  2
                        4  --------------------------------  6 & 8
                        5  --------------------------------  20
                        6  --------------------------------  4
                        7  --------------------------------  7
                        8  --------------------------------  4
                       20  --------------------------------  5



          e.   DEC VAX 4000 WORKSTATIONS:

               NOTE: CalComp does not provide a serial cable for the
               DEC VAX.

               The following is a known working pin-out for CalComp
               plotters and the DEC VAX. This cable pin-out is a
               reference only. For further information, please consult
               with your DEC VAX documentation and technical support
               services.

               REMEMBER: You must attach the Null modem Adapter (P/N
               21617-0019) to the plotter (25 pin) end of this cable.

                       DEC                            Plotter Port:
                       VAX                            25 pin male
                     connector       connect as         connector
                       Pin #         shown below          Pin #
                    ==============================================
                        1  --------------------------------  8
                        2  --------------------------------  3
                        3  --------------------------------  2
                        5  --------------------------------  7
                        6  --------------------------------  6
                        7  --------------------------------  4
                        8  --------------------------------  5



          f.   DATA GENERAL WORKSTATIONS:

               NOTE: CalComp does not provide a serial cable for Data
               General.

               The following is a known working pin-out for CalComp
               plotters and some Data General computers. This cable
               pin-out is a reference only. For further information,
               please consult with your Data General documentation and
               technical support services.

               REMEMBER: You must attach the Null modem Adapter (P/N
               21617-0019) to the plotter (25 pin) end of this cable.

                       Data                             Plotter Port:
                      General                            25 pin male
                     connector      connect as            connector
                       Pin #        shown below             Pin #
                    =================================================
                         1  --------------------------------  1
                         2  --------------------------------  3
                         3  --------------------------------  2
                         4  --------------------------------  20
                         5  --------------------------------  8
                         6  --------------------------------  6
                         7  --------------------------------  7
                         8  --------------------------------  4



C.   CUSTOM CABLE INFORMATION:

     Specially designed cables are available which enable you to
     reliably exceed the industry-standard limits in cable length for
     both Centronics parallel and RS-232 serial cables.

     These limits are:   12 feet for Centronics parallel
                         50 feet for RS-232 serial

     Special serial and parallel cables with lengths up to 300 feet (or
     more) are available from the following vendors:

     1.   Buffalo Products Inc.    (800) 345-2356

     2.   The Black Box Corp. (412) 746-0746

     3.   INMAC Corp.    (800) 547-5444

     4.   NewData Inc.        (908) 842-5757